New 32-bit DSP technology
Ultra-low vibration and noise
Parameters automatically match motor function after power-on
Variable current control greatly reduces motor heating
The current is automatically halved when stationary
Opto-isolated differential signal input
Photoelectric isolation, alarm output
Impulse response frequency up to 500KHz (factory default 200KHz)
Voltage range DC 24-80Vdc/AC 20-60Vac AC DC universal
The current is easy to set and can be selected between 1.0-6.0A.
The subdivision setting range is 200-51200, higher subdivisions can be customized
With overvoltage, undervoltage, overcurrent and other protection functions
With rising edge/falling edge, IO control spontaneous pulse, single/double pulse, high response/high speed and low vibration, self-test function
Mechanical Drawing
Electrical Parameter
Electrical Parameter | Minimum value | Typical value | Maximum value | Unit |
Output | 1.0 | - | 60 | A |
Supply Voltage | 24/20 | 24/36/48 | 80/60 | Vdc/Vac |
Logic input curren | 6 | 10 | 16 | mA |
Logic input voltage | 5 | 5 | 24 | Vdc |
Pulse frequency | 0 | - | 200 | KHZ |
High level pulse width | 1.5 | - | - | US |
Insulation resistance | 100 | - | - | MΩ |
Product Wiring Diagram
Working Current Setting | ||||
Peak | RMS | SW1 | SW2 | SW3 |
Default[RMS=1.0A] | off | off | off | |
2.1A | 1.5A | on | off | off |
2.7A | 1.9A | off | on | off |
3.2A | 2.3A | on | on | off |
3.8A | 2.7A | off | off | on |
4.3A | 3.1A | on | off | on |
4.9A | 3.5A | off | on | on |
6.0A | 4.3A | on | on | on |
※SW4 for function,when SW4=off,for Half Current,when SW4=on,for Full Current.
Motor Subdivision Setting | |||||
Pulse/rev | SW5 | SW6 | SW7 | SW8 | IO/RPM |
Default[200] | on | on | on | on | 10 |
400 | off | on | on | on | 20 |
800 | on | off | on | on | 30 |
1600 | off | off | on | on | 40 |
3200 | on | on | off | on | 50 |
6400 | off | on | off | on | 60 |
12800 | on | off | off | on | 80 |
25600 | off | off | off | on | 100 |
1000 | on | on | on | off | 120 |
2000 | off | on | on | off | 150 |
4000 | on | off | on | off | 200 |
5000 | off | off | on | off | 250 |
8000 | on | on | off | off | 300 |
10000 | off | on | off | off | 350 |
20000 | on | off | off | off | 450 |
25000 | off | off | off | off | 600 |
Functionsetting | ||
SW9:Edge sel,off=Fall;on=Rise | ||
SW10:S-Filter,off=4ms;on=10ms | ||
Mode sel | SW11 | SW12 |
IO internal spontaneous pulse | on | on |
Self-test check | on | off |
CW/CCW | off | on |
PLU+DIR | off | off |